Prevista Dry Plus urinal module BH 1120‑1300
for urinal flush plates for Prevista (manual and touchless flush actuation), for universal water connection
Year built (from): | 01.11.2022 |
Trade mark rights exist for this document; for further information, go to viega.com/legal .
The information in this instruction manual is directed at the following groups of people:
Heating and plumbing experts and trained personnel
Drywall builders
Individuals without the abovementioned training or qualification are not permitted to mount, install and, if required, maintain this product. This restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
This symbol warns of possible life-threatening injury.
This symbol warns of possible serious injury.
This symbol warns of possible injury.
This symbol warns of possible damage to property.
This symbol gives additional information and hints.
This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e.g. EN) and/or in Germany (e.g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/Germany. These should serve as recommendations in the absence of corresponding national regulations. The relevant national laws, standards, regulations, directives and other technical provisions take priority over the German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation.
The following standards and regulations apply to Germany / Europe and are provided as a support feature.
Scope / Notice | Regulations applicable in Germany |
---|---|
Suitable stud frames | DIN 18183 |
The Prevista Dry Plus urinal module is designed for mounting in a Prevista Dry Plus pre-wall construction.
The urinal module is compatible with all common urinal ceramics, even with spray head.
Waste elbow |
---|
Fitting connection |
DN50 |
Rp ½ |
Metal stud frames
Prevista Dry Plus pre-wall constructions
The wall constructions must comply with the regulations in section Regulations from section: Fields of application / Mounting conditions .
The two vertical rails, which surround the module, must be open towards the module and have an inner distance of 420 mm.
Secure the module onto the open mounting rail with the slot nuts supplied:
Insert the slot nuts into the opening of the module.
Push the slot nuts in until they engage.
Align the urinal module.
Fasten the slot nuts.
Bend the sides of the metal bars of all rails.
Attach the module to the stud frame using the supplied screws.
Seal the connection end of the urinal water path.
Screw the threaded end of the adapter elbow and the connection end of the urinal water path.
Hold in place with a fork spanner on the underside of the urinal water path.
Insert the water inlet into the transition angle.
Press the connection.
Mount the inspection shaft.
Determine the height of the wall plate.
Observe the dimensions of the urinal flush plate and the ceramic.
Loosen the screws on the wall plate, but do not unscrew them.
Adjust the height of the wall plate.
Tighten the screws on the wall plate again.
Mount a drain elbow.
Turn in the threaded rods by hand.
Tighten the nuts of the threaded rods with a fork spanner.
Place the protective caps on the threaded rods.
Make the water connections.
Cut out the recesses for the drain elbow and the threaded rods.
Cut the plasterboard cladding panel to size.
Clad the module with suitable plasterboard cladding panels.
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.