Viega Eco Plus washbasin element
for WB with single-hole fitting
Year built (from): | 01.01.2010 |
Trade mark rights exist for this document, further information can be found at www.viega.com/legal-notices.
The information in this instruction manual is directed at the following groups of people:
Heating and sanitary professionals and trained personnel
Drywall builder
It is not permitted for individuals without the abovementioned training or qualification to mount, install and, if required, service this product. This restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
This symbol warns against possible life-threatening injury.
This symbol warns against possible serious injury.
This symbol warns against possible injury.
This symbol warns against possible damage to property.
Notes give you additional helpful tips.
This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e. g. EN) and/or in Germany (e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/Germany. These should serve as recommendations in the absence of corresponding national regulations. The pertinent national laws, standards, regulations and guidelines, as well as other technical guidelines, have priority over German/European guidelines in this manual: The information is not binding for other countries and territories and should, as mentioned, be considered as support.
The Viega Eco Plus washbasin element is suitable for mounting on wall constructions in acc. with DIN EN 1996‑1‑1, DIN 1045 and support profiles in acc. with DIN 18183.
The element is compatible with all common washbasin ceramics, even with larger projection (barrier-free).
The washbasin element fulfils the requirements in acc. with DIN 4109 as well as the increased requirements in acc. with DIN 4109 (supplementary sheet 2) and the requirements in acc. with VDI 4100 SSt I-SSt III.
The product has the following technical data:
drain elbow |
---|
Rubber nipple |
Hole diameter for fixing in wooden frame construction |
Construction height |
DN 40 / 50 |
DN 40 / 30 |
11 mm |
Article 704 087 – 980
mm
|
The fixing set model 8173 is required to secure.
With a desired installation depth of 75 mm (see dimension * in dimensional drawing Installation dimensions ), you will require the drain elbow model 8113.21.
The element can be mounted on the following walls:
masonry walls in acc. with DIN EN 1996‑1‑1
concreted walls in acc. with DIN 1045
metal support profile in acc. with DIN 18183
The element may only be mounted on even wall surfaces.
With the construction height, the marked height of the upper edge of the finished floor must be observed.
The following tools are required for the mounting of the washbasin element:
drill with 10 mm drill bit
ratchet with sockets: 13 mm / 17 mm
fork or ring spanner: 13 mm / 17 mm
Masonry and concreted walls
You should use a support bracket (model 8165) when mounting multiple washbasin elements with an interval of > 490 mm. Observe the instructions for use of the support bracket when mounting.
Determine and mark fixing points.
x = mounting height 1110 mm or 960 mm
Drill holes.
Mount the fixing set with the fork spanner (SW 13).
Align height of element.
Whilst doing so, observe the markings on the element.
Determine construction height in accordance with the on-site marking of the upper edge of the finished floor.
x = Observe the instructions of the washbasin manufacturer.
The construction height must be determined exactly.
There are only limited possibilities available to remedy errors made during this assembly step,
Construction height
.
Set the installation depth of the element with the fork spanner (SW 17).
Remove WC element and drill floor holes.
Attach element to the floor using the fork spanner (SW 13) and the screws and dowels supplied.
Mount drain elbow in mounting bracket.
Secure with a bracket.
Set height of the drain elbow (50–100 mm).
Mount threaded bolts.
The fixing interval is dependent on the ceramic. It is normally 280 mm.
Set connections for wall plates.
Observe the instructions of the ceramic manufacturer.
Setting range 80–360 mm
Make water connections.
Double-clad element (2 x 12.5 mm).
The element can be inserted into the 50 mm and 75 mm support profiles.
Determine the fixing points.
Align element.
Mount drain elbow and threaded bolts.
If necessary, adjust the pre-mounted foot depth from 75 mm to 50 mm: Pull out foot and turn by90°.
Attach element to the floor using the fork spanner (SW 13) and the screws and dowels supplied.
Determine construction height in accordance with the on-site marking of the upper edge of the finished floor.
Align height of element.
Whilst doing so, observe the markings on the element.
x = Observe the instructions of the ceramic manufacturer.
The construction height must be determined exactly.
There are only limited possibilities available to remedy errors made during this assembly step,
Construction height
.
Screw element together laterally with the support profiles.
Set connections for wall plates.
Observe the instructions of the ceramic manufacturer.
Setting range 80–360 mm
Make water connections.
Double-clad element (2 x 12.5 mm).
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.